Chat with us, powered by LiveChat
Subperiosteal Implants

How subperiosteal implants Evolved? A Historical overview

Origins (1940s): The concept of subperiosteal implants was pioneered in the early 1940s by Dr. Gustav Dahl in Sweden. Dahl’s approach involved fabricating a custom metal framework (initially cast in cobalt–chromium alloy) that sat on top of the jawbone, beneath the periosteum, with posts protruding through the gum to support dentures. In the late 1940s and 1950s, this idea was introduced in the United States by Gershkoff and Goldberg, gaining popularity as a solution for fully edentulous patients who lacked enough bone for traditional “root-form” implants. During their mid-century heyday (1950s–1970s), subperiosteal implants provided many patients the first chance at fixed prostheses when severe bone loss made conventional implants impossible.

Why They Fell Out of Favor: By the 1980s, subperiosteal implants had developed a bad reputation due to multiple issues. Early techniques required taking a direct impression of the bone during surgery (after reflecting large flaps), which was imprecise and traumatic. The resulting metal frames often had poor fit, leading to instability. Lack of true osseointegration (the frames rested on bone without integrating) combined with fit issues meant that chronic inflammation, infection, and progressive bone resorption were common. Long-term studies from the era reported only ~50–60% survival at 15 years, with frequent complications. Additionally, frame materials like cobalt–chrome, while strong, were relatively less biocompatible than titanium and could irritate tissues. By the late 1980s, the advent of Brånemark’s titanium screw implants (which achieved reliable osseointegration) shifted implant dentistry toward endosseous solutions. Given the superior predictability of root-form implants, subperiosteals largely fell into obscurity for several decades.

Why Subperiosteals Are Making a Comeback In Dentistry?

In recent years, there has been a renaissance of interest in custom subperiosteal implants as a niche solution for extreme atrophy cases. Several factors explain this resurgence:

    • Advanced Imaging (CBCT/CT Scans): Modern cone-beam CT or high-resolution medical CT scans allow a non-invasive, highly accurate 3D model of the patient’s jaw to be obtained. This eliminates the need for a second “impression surgery” and ensures the implant framework is designed to precisely match the bone topography. Digital scanning of soft tissues (intraoral scans) further helps in planning the frame’s shape relative to the gum tissue.

    • CAD/CAM Design & 3D Printing: The use of computer-aided design/manufacturing means today’s subperiosteal frameworks are virtually designed on a computer model of the jaw. Engineers can simulate the fit and even run finite element analysis (FEA) to optimize stress distribution. The frameworks are then either milled from titanium billet or 3D-printed (using laser sintering/melting) with exceptional precision. The result is a patient-specific implant that conforms perfectly to the bone surface, a world of difference from the “best-guess” hand-crafted castings of the past.

    • Materials and Surface Tech: Contemporary subperiosteal implants are made from medical-grade titanium (either commercially pure or Ti–6Al–4V alloy), offering superb biocompatibility, strength, and reduced weight. Titanium’s acceptance by the body helps soft tissue integration and minimizes adverse reactions. Modern processing also allows surface modifications – for example, strategic sandblasting or porous texturing of certain regions to encourage bone adhesion and stability. (By contrast, older designs in chrome-moly steel or Co-Cr had none of these advantages and often elicited soft-tissue problems.)

    • Improved Surgical Protocols: Current protocols emphasize minimally invasive approaches and sound soft-tissue management. Unlike the two-stage process historically (surgery to impression, then surgery to place frame), a custom subperiosteal today is placed in one surgical stage. Soft tissues are handled delicately, and often advances like PRF membranes or flap techniques are used to promote healing. The result is often faster recovery than extensive bone grafting or zygomatic implant surgery.

    • An Alternative to Zygomatic Implants: Perhaps the biggest driver is the need for alternatives in severe maxillary atrophy cases. Zygomatic implants (anchored in the cheekbone) are a graftless solution for no-bone upper jaws, but they come with technique sensitivity and risk of serious complications (sinusitis, sinus perforation, even orbital injury). Recent comparative research has shown subperiosteal implants can achieve similar implant survival (≈97% at 5 years) to zygomatics, with fewer sinus complications and less peri-implantitis. In one 5-year study, zygomatic cases had sinus issues in 12.4% of implants, whereas custom subperiosteals had virtually none of those sinus problems and a lower peri-implantitis rate (5.6%). Subperiosteal frames also can be removed or revised more easily if something fails, whereas a failed zygomatic implant leaves a challenging void. For patients who cannot endure a sinus lift or have had All-on-X graftless methods fail, a custom subperiosteal offers a safer, customizable solution in anatomically complex situations. Immediate function is still possible (many subperiosteal cases are loaded with a provisional prosthesis shortly after surgery), but without the need to engage remote anchor points like the zygoma.

Subperiosteal Implants

What is the Difference Between Old VS New Subperiosteal Implants?

Modern custom subperiosteal implants differ from the old ones in almost every aspect of design and fabrication:

    • One-Piece vs. Sectional Frames: Historically, a subperiosteal implant was often a one-piece cast framework per arch (e.g. a full mandibular horseshoe). Contemporary approaches allow for sectional or two-part frame designs when appropriate. For instance, in the maxilla a left and right framework can be made to support posterior segments without a connecting bar in the front, or two halves that meet in the midline. Using two smaller frames can simplify insertion and reduce the overall bulk, especially in partially edentulous cases. New “All-on-Frame” style treatments sometimes use bilateral implants just for the posterior regions (preserving anterior teeth or avoiding anatomic structures). The flexibility of CAD design means the frame can be split into components if it improves the fit or surgery—something not feasible with the old cast fabrication. Whether one-piece or sectional, all modern frames are designed to rigidly fixate to the bone with osteosynthesis screws for primary stability. The use of screws (often 4–6 per frame) ensures the custom implant does not rely on tissue pressure alone for stability as some early designs did.

    • Material Upgrade: Classic subperiosteals were cast from cobalt–chromium or Vitallium alloys. These were strong but could be heavy and were not osteophilic. Today’s implants are almost exclusively titanium. For maxillary (upper arch) cases, some manufacturers prefer Grade 4 commercially pure titanium (a high-purity form of Ti with excellent biocompatibility), whereas Grade 23 Ti-6Al-4V ELI alloy (extra-low interstitial version of Grade 5 alloy) is often used for mandibular frames that demand higher tensile strength. The choice can depend on the arch: the softer bone and sinus proximity in the upper jaw favor a slightly more flexible pure titanium, while the lower jaw’s higher bite forces warrant the stronger alloy. In either case, titanium frames are far more biocompatible, inducing a gentle fibrous integration with the bone and supporting tissues. They are also much lighter than the old chrome frames. Notably, some new frameworks are additively manufactured (3D-printed) from Ti-6Al-4V powder and then post-processed (heat-treated and surface-finished) to optimize their mechanical properties. Others are milled from solid titanium billets with 5-axis CNC machines, achieving excellent surface accuracy. Anodizing and polishing techniques are sometimes applied to specific areas of the frame – anodization can reduce surface roughness on the outer surfaces, which some providers claim helps prevent soft-tissue dehiscence by making the frame smoother.

    • Improved Fit and Anatomical Adaptation: With digital design, the new subperiosteal implants hug the bone with extreme precision, whereas older ones often had gaps due to impression distortion. The precision fit means less micromotion and less irritation. Importantly, the design can be tailored to avoid critical anatomical structures. For example, the modern subperiosteal framework is carefully contoured so that it avoids encroaching on any muscle origins or insertions in the jaw. (Encroachment on muscle attachments in earlier designs often led to chronic inflammation or the frame becoming dislodged by muscle movement.) The custom CAD approach allows engineers and surgeons to respect the “muco-skeletal junction” – the transition where flexible mucosa meets attached gingiva and periosteum. By keeping the frame within zones of attached tissue and not crossing into movable mucosa or muscle, the risk of postoperative soft-tissue breakdown is greatly reduced. As one clinical report emphasized, the subperiosteal implant should be designed to sit on bone without impinging on peripheral muscle attachments, ensuring the patient’s normal muscle function does not disturb the implant. This level of design finesse simply wasn’t possible in the past.

    • Prosthetic Connection Improvements: Older subperiosteals typically had integral posts for denture attachment; these could be bulky and hard to align. Today, most custom subperiosteals incorporate transepithelial abutments (multi-unit abutments) as part of the frame or attached to it, positioned ideally for the prosthetic plan. Using CAD, the angulation and spacing of these abutment posts are decided before manufacturing, allowing the final prosthesis to have a passive, parallel fit. In essence, the restorative outcome is designed first, and the implant is engineered to support that outcome. This contrasts with the older approach of placing a frame and then trying to adapt a denture to whatever emergent posts you got. The modern method yields a more predictable prosthetic phase with correct occlusion and less stress on the implants.

In short, new-generation subperiosteal implants have little in common with their ancestors aside from the basic concept of sitting on top of bone. The combination of superior materials, precise fit, and thoughtful design (aided by computer modeling) has addressed most of the historical drawbacks.

Table: Titanium Material Choices by Arch

Arch (Jaw) Common Material Choice Rationale
Maxilla (Upper) Grade 4 CP Titanium (pure) Softer bone; slight flexibility and excellent biocompatibility suit sinus area and thin bone.
Mandible (Lower) Grade 23 Ti-6Al-4V ELI Alloy Higher strength for dense bone and greater bite forces; ensures frame rigidity under load.

Note: Both materials integrate well with tissues; the selection often balances strength vs. flexibility for the specific case. All modern subperiosteal frames use medical-grade titanium, avoiding the corrosion and weight issues of older Co-Cr implants.

Surgical Considerations: Respecting Anatomy to Ensure Success

A critical lesson learned from earlier failures is the importance of respecting the anatomical boundaries during design and placement of a subperiosteal implant. The term “muco-skeletal junction” in this context refers to the demarcation where the fixed, bound-down tissues (attached gingiva and periosteum over bone) meet the flexible, mobile mucosal tissues. For a subperiosteal frame to remain stable and infection-free, it must remain in the realm of fixed tissues. If the frame extends into movable mucosa, each time the patient talks or chews, the movement can create a pocket or cause rubbing that invites soft tissue breakdown.

Similarly, the custom framework must be trimmed to avoid any muscle origin or insertion sites on the jaw. Muscles like the mentalis, buccinator, mylohyoid, and others attach along the jaw surfaces; the implant should not overlap these attachments. If it does, muscle activity could dislodge the frame or cause constant pressure leading to ulceration. Modern CAD design allows the technician (often in collaboration with the surgeon) to delineate these no-go zones on the 3D model. The resulting implant frame is sometimes described as “scalloping around” the critical anatomical features. For example, in the mandible, the frame might stop short of the mylohyoid ridge (where the mylohyoid muscle attaches) and avoid the genial tubercle area to leave the genioglossus muscle undisturbed. In the maxilla, care is taken not to impinge on the thin periosteum over the sinus wall or the insertions of facial muscles near the zygomatic arch.

Soft tissue management during surgery is equally vital. A precise surgical flap design is used to ensure there is enough keratinized tissue to cover the frame edges. The frame is seated and any sharp edges are smoothened or kept well away from the flap margins. Tension-free primary closure is the goal to prevent dehiscence. Some advanced protocols even utilize things like a buccal fat pad flap in the maxilla to cover the frame, adding a vascularized layer over it (as depicted in recent clinical techniques). The bottom line is that the interface between the custom implant and the patient’s tissues must be harmonious. When the implant is well-designed anatomically and the soft tissue is carefully closed over it, the risk of exposure or infection drops dramatically.

Post-operatively, maintaining excellent oral hygiene around the transmucosal posts is critical. Patients are put on chlorhexidine rinses and sometimes prophylactic antibiotics. Because subperiosteal implants don’t rely on osseointegration, the soft tissue seal is the primary defense against bacteria; thus, regular follow-ups for professional cleaning around the abutments are recommended (typically every 3–6 months). With good surgical and home care, the soft tissue adapts and matures around the abutments similar to the way gums seal around a natural tooth or a well-healed implant.

Subperiosteal Implants

WHat are the Top Leading Dental Companies in Subperiosteal Implants?

As the demand for custom subperiosteal implants grows, a number of specialized companies (distinct from general dental labs) have emerged to design and manufacture these patient-specific frameworks. Here are a few notable players and considerations:

    • AB Dental Devices (AB PSI): Originally based in Israel, AB Dental has a strong U.S. presence and offers a full custom subperiosteal implant system (marketed as patient-specific implant, PSI). They were an early adopter of revived subperiosteals and report stable long-term results. AB’s system uses proprietary CAD/CAM design and their frames feature surface nano-structures to promote cell activity and healing. They have collaborated globally (e.g., with providers in the UAE) to expand this solution. In the U.S., AB Dental’s custom implant package typically includes the design, the 3D-printed titanium frame, multi-unit abutments, and surgical accessories.

    • KLS Martin (Individual Patient Solutions – IPS Implants): KLS Martin, a German-headquartered surgical manufacturer with U.S. offices, produces custom maxillofacial implants. Their IPS system (often used for mandibular reconstruction plates and orbital implants) has been applied to subperiosteal implant fabrication as well. They utilize laser melting of titanium and are known for precision. KLS Martin mostly works directly with oral and maxillofacial surgeons and provides a planning service to ensure the implant fits the defect or atrophic site exactly.

    • Panthera Dental: Based in Canada (with a U.S. arm in California), Panthera launched a dedicated CAD/CAM subperiosteal implant division in 2018. Panthera uses Grade 23 titanium for all their frames and a proprietary software workflow. They deliver the finished implant along with a 3D printed model of the patient’s jaw for the surgeon’s reference. Panthera’s system is known for its high precision and they emphasize a single-stage surgery approach. Being a well-established name in CAD/CAM prosthetics, Panthera is a go-to for many prosthodontists dealing with these cases.

    • Marver Med: A U.S.-based precision manufacturing company, Marver Med specializes in CNC machining for medical implants. They are an OEM manufacturer that can fabricate subperiosteal implant frames and components for other brands or dental surgeons. Marver Med’s promotion highlights their expertise in producing subperiosteal frames, abutments, and screws with ISO-certified quality. While not a consumer-facing brand for clinicians, they likely supply parts or offer contract manufacturing for custom implant cases – their inclusion in market reports indicates they are a significant player in the fabrication side.

    • BoneEasy: Based in Portugal, BoneEasy is noteworthy globally for custom implants (including a new “Implantize Compact” subperiosteal concept). They’re not U.S.-based, but U.S. surgeons sometimes collaborate through international labs to access BoneEasy’s products. Their frames are 3D-printed and they’ve incorporated design features like perforations in the plate to allow soft tissue in-growth.

    • Others: Avinent (Spain) has been actively involved in custom subperiosteal implant development and has hosted consensus conferences on the topic. B&B Dental (Italy) fabricates custom subperiosteals and even provides surgical guides and planning services, as evidenced by recent technical reports. Integra Implants (Poland) developed a branded subperiosteal known as “MaI Implant” used in research comparisons. These are not U.S. companies, but knowledge of their work is spreading in the U.S. specialist community through conferences and journals.

Evidence: What the Research Says Now

Contemporary clinical research is increasingly validating custom subperiosteal implants as a viable – even superior in some aspects – option for patients with extreme bone loss or prior All-on-X failures. Key findings from recent studies include:

    • Comparable Success to Conventional Implants: Modern subperiosteal implants have reported high survival rates, often in the mid-90% range at 3–5 years. For example, a 2025 five-year study by Zielinski et al. showed subperiosteal implants in atrophic maxillae had a 97.1% survival, virtually identical to zygomatic implants at 96.3%. Notably, the complication profile was different – subperiosteals had significantly fewer sinus complications and better soft-tissue outcomes than the zygomatic cohort. This suggests that when designed and placed well, subperiosteal frames can be just as clinically reliable as the alternative graftless solutions.

    • Successful Immediate Loading: Case series have documented that custom subperiosteal implants can be loaded with a provisional fixed prosthesis either same-day or within a few days after surgery, giving patients immediate function. This immediate loading is a big quality-of-life improvement (no long waiting period without teeth). In a published consensus, experts noted that the ability to recover esthetics and function immediately is a major advantage of the new-generation subperiosteals in the maxilla. Naturally, careful soft tissue management is required when loading immediately, to avoid excessive pressure on the healing gums.

    • Bone Preservation and Health: Unlike old reports where underlying bone often resorbed under the frame, newer studies are finding minimal bone loss beneath modern subperiosteal implants. One technical study (Sassani et al., 2025) followed 21 custom subperiosteals in atrophic maxillae and found no significant bone resorption under the abutment posts after 1 year (mean ~0.18 mm) and stable bone levels up to 4 years. The careful distribution of forces and improved adaptation likely contribute to this encouraging outcome. Soft tissue health also appears stable long-term; for instance, bleeding on probing around subperiosteal abutments actually decreased over time in that study (from 10% of sites at 6 months to only 2.5% at 4 years), indicating good maturation of the tissue interface.

    • Rescue for All-on-4/All-on-X Failures: Clinicians are reporting success using custom subperiosteals as a “Plan B” when bone is too compromised for even zygomatics or when previous All-on-4 implants have failed. In situations of catastrophic graft loss or implant failure where the ridge is severely scarred and thinned, a subperiosteal can sometimes be designed to capitalize on whatever basal bone remains. A 2023 publication by Van den Borre et al. noted that many authors are advocating bringing back subperiosteal implants as an alternative to extensive regenerative surgeries. The literature is now populated with case reports of patients who, after multiple failed grafts or implant attempts, were finally rehabilitated using a custom subperiosteal implant and were still doing well several years later. These success stories underscore that custom subperiosteals are not a step backward, but rather a modern re-imagining of an old idea that fits a specific niche of patient needs.

    • Quality of Life Improvements: It’s worth noting that for the patient, avoiding a hip graft or a sinus lift and getting teeth quickly can be life-changing. Studies that surveyed patients who received modern subperiosteal implants found high satisfaction due to the shortened treatment time and the fact that they could avoid donor-site surgery. Many reported being able to eat and smile with confidence soon after the procedure, which had a positive impact on overall morale – an outcome that is hard to quantify but very real.

Of course, the evidence base for custom subperiosteals is still maturing. While 5-year data are promising, we will continue to collect 10-year and longer-term data. So far, the trajectory is positive: multiple independent centers around the world have published results aligning with the theme that “the lost art of subperiosteal implants is worth revisiting”.

Subperiosteal Implants

Conclusion | Subperiosteal Implants

Custom subperiosteal implants have transitioned from a historical footnote to a state-of-the-art solution for some of dentistry’s hardest cases. For the right patient – someone with too little bone for standard implants and a desire to avoid extensive grafting – a digitally designed, 3D-printed subperiosteal implant offers a fast, predictable path to a new set of teeth. The key is leveraging modern imaging and manufacturing to overcome the shortcomings of old techniques. As specialists, staying informed about these advances empowers us to treat previously “untreatable” cases. In a broader sense, the resurgence of subperiosteals is a testament to how technology can revive and refine an old idea, turning failure into success.

With high success rates being documented and increasing industry support, the custom subperiosteal implant is no longer a last resort from the past – it’s an evolving contemporary therapy. By understanding its history, indications, and implementation, dental professionals can ensure we use this tool wisely and maximize outcomes for our patients with extreme atrophy.

Sources: Subperiosteal implant historical data and design improvements; modern CAD/CAM techniques and outcomes; cost and fabrication details; clinical comparisons with zygomatic implants; and consensus recommendations for use of custom subperiosteal implants.